TeeJet Flow Regulator Orifice Plate | CP4916-52
Stainless Steel restriction orifice plate is a device used to restrict flow. It reduces flow and pressure from the upstream side to the downstream side.
CP4916-52 will allow water/chemical of 0.118 at 5 psi - 0.410 at 60 psi Gallons Per Minute
To determine the orifice plates you need, use the following equations:
GPM (Per Nozzle) = GPA x MPH x W / 5,940
GPM = 5,940 x GPM (Per Nozzle) / MPH x W
Tabulated flow rates are for spraying water into air at atmospheric pressure. If your application creates backpressure, or if spraying into a liquid, measure and calibrate to ensure proper application rates.
W = Nozzle spacing (in inches) for broadcast spraying.
= Spray width (in inches) for single nozzle, band spraying or boomless spraying.
= Row spacing (in inches) divided by the number of nozzles per row for directed spraying.
Note: Always insert orifice plate with side marked with number facing the outlet. Always double check your application rates. Tabulations are based on spraying water at 70°F.