null
Customer Service Hours: MONDAY-FRIDAY, 8AM-5PM CT
Free Shipping on Orders Over $229+ Exclusions Apply

Pioneer FEM Series Non-Spill Nipple | FEM-502-8FP


$43.95
SKU:
FEM-502-8FP
UPC:
08250600202
Weight:
0.54 LBS
Shipping:
Calculated at Checkout
Hydraulic Couplings:
FEM Series

Pioneer FEM Series Non-Spill Nipple | FEM-502-8FP

FEM Series couplings meet or exceed ISO 16028 design and performance requirements. The flush valves eliminate spillage and air inclusion when connecting and disconnecting. Coupler and nipple bodies have a modular design with increased flexibility for end port options. FEC nipples provide a connect-under-pressure option for trapped residual pressure.


Features:

  • Flush, non-spill valving
  • Global interchangeability with other ISO 16028 compliant couplings
  • Hardened nipple bodies
  • Sleeve-Lok design standard
  • Connect-under-pressure FEC nipple option
  • Protective zinc nickel plating

Specifications:

  • Body Size: 1/2"
  • Nipple Part Number: FEM-502-8FP
  • Port End: 1/2-14 NPTF
  • Length: 3.13"
  • Coupled Length (when connected to corresponding coupler): 5.74"
  • Largest Diameter: 1.57"
  • Wrench Flats: 36mm
  • Weight(lbs): 0.84

Applications Include:

  • Skid loader attachments
  • Hydraulic tools

Materials of Construction:

  • Body: Steel
  • Finish: 1/4”, 5/8” to 1” Zinc with clear trivalent chromate 3/8” & 1/2” Zinc Nickel
  • Valve: Flush face valving
  • Seal: Polyurethane and Nitrile

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

  • This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
  • The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
  • To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.